Labotect

Puncture Needles

There are different needles and tubes, as well as echo markings and plugs.

Labotect ovarian biopsy needles and sets are developed for medical use in the field of assisted reproduction.

Advantages:

  • Needles and sets for follicular puncture
  • Facet bevel
  • Ergonomic handle
  • Grinded or corroded echo marking
  • Validated ETO-sterilisation
  • MEA / LAL tested
  • Medical device class IIa

(Picture shows needles with grinded echo marking on the left side and with corroded echo marking on the right side)

PunctureNeedles_english_12_012022.pdf

Single lumen puncture sets
with corroded echo marking, without flushing tube:

REFNeedle length (mm)Outer diameter of the needle (mm / G)Plug for tubes with ... mlLength of tubing from needle to plug (mm)Length of tubing from plug to aspirator (mm)Luer connection on plug              
134413001.4 / 171413001000yes
151383301.0 / 191413001000yes
167833001.4 / 1714800800yes
167853301.0 / 1914800800yes



Single lumen puncture sets
with corroded echo marking and flushing tube:

REFNeedle length (mm)Outer diameter of the needle (mm / G)Plug for tubes with ... mlLength of tubing from needle to plug (mm)Length of tubing from plug to aspirator (mm)Luer connection on flushing tube
134433001.4 / 171413001000yes

Length of tubing for flushing: 1000 mm

REFNeedle length (mm)Outer diameter of the needle (mm / G)Plug for tubes with ... mlLength of tubing from needle to plug (mm)Length of tubing from plug to aspirator (mm)Luer connection on flushing tube
164453001.4 / 171475030yes

Length of tubing for flushing: 750 mm


Single lumen puncture sets
with grinded echo marking, without flushing tube:

REFNeedle length (mm)Outer diameter of the needle (mm / G)Plug for tubes with ... mlLength of tubing from needle to plug (mm)Length of tubing from plug to aspirator (mm)Luer connection on plug              
134383001.4 / 171413001000yes
13451*3001.4 / 171413001000no
13452*3001.4 / 17145001000no
13452L*3001.4 / 171410001000no

*with firm tubing


Double lumen puncture sets
with grinded echo marking and flushing tube:

REFNeedle length (mm)Outer diameter of the needle (mm / G)Plug for tubes with ... mlLength of tubing from needle to plug (mm)Length of tubing from plug to aspirator (mm)Luer connection on flushing tube
134633301.6 / 16143901000yes

Length of tubing for flushing: 350 mm

REFNeedle length (mm)Outer diameter of the needle (mm / G)Plug for tubes with ... mlLength of tubing from needle to plug (mm)Length of tubing from plug to aspirator (mm)Luer connection on flushing tube
167843301.6 / 1614800800yes

Length of tubing for flushing: 800 mm


back

Single lumen puncture sets are available

With corroded echo marking for aspiration only:

REF 13441, 13444, 15138

With corroded echo marking for aspiration and flushing:

REF 13443

With grinded echo marking for aspiration only:

REF 13436, 13438, 13440, 13450, 13451, 13452

Double lumen puncture sets are available
 
With grinded echo marking for aspiration and flushing:

REF 13463

Puncture needles are available

With corroded echo marking for aspiration only:

REF 13427

more information